Fluke 117C Digital Multimeter, Non-Contact AC Voltage Detection, Measures Resistance/Continuity/Frequency/Capacitance/Min Max Average, Automatic AC/DC Voltage Selection, Low Impedance Mode

Fluke 117C Digital Multimeter, Non-Contact AC Voltage Detection, Measures Resistance/Continuity/Frequency/Capacitance/Min Max Average, Automatic AC/DC Voltage Selection, Low Impedance Mode

£519.98
Ex Tax: £519.98
Product Code: 1983059
Stock In Stock

Product Description

The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.


  • VoltAlert technology for non-contact voltage detection
  • AutoVolt automatic AC/DC voltage selection. DC millivolts - Range : 600.0 mV, Resolution : 0.1 mV
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True RMS for accurate measurements on non-linear loads.Operating temperature:-10°C to +50°C.Battery life:400 hours typical, without backlight


AutoVolt automatic ac/dc voltage selection

LoZ: Helps prevent false readings due to ghost voltage

 True-rms for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30 seconds) Resistance, continuity, frequency and capacitance Min/Max/Average to record signal fluctuations Compatible with optional magnetic hanger (ToolPak) for hands free operation CAT III 600 V safety rate

Brand  Fluke 117C
Mode Fluke 117C
Power Source 9V  batteries required. (Not included)
Style  Multimeter Standard
Item Weight 550 Grams
Item Dimensions LxWxH 6.57 x 3.31 x 1.81 inches
Measurement Type Multimeter
Measurement Accuracy ‎+/-0.5%

 

Specifications:

Maximum voltage between any terminal and earth ground 600 V

Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2

Fuse for A input 11 A, 1000 V FAST Fuse (PN 803293)

Display Digital: 6,000 counts, updates 4 per second

Bar graph 33 segments, updates 32 per second

Operating temperature -10 °C to + 50 °C

Storage temperature -40 °C to + 60 °C

Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery life 400 hours typical, without backlight

Accuracy Specifications

DC millivolts Range/Resolution 600.0 mV / 0.1 mV

Accuracy ± ([% of reading] + [counts]): 0.5% + 2

DC volts Range/Resolution 6.000 V / 0.001 V

60.00 V / 0.01 V

600.00 V / 0.1 V

Accuracy ± ([% of reading] + [counts]): 0.5% + 2

Auto volts Range/Resolution 600.0 V / 0.1 V

Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)

4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts¹ true-rms Range/Resolution 600.0 mV / 0.1 mV

Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)

2.0 % + 3 (500 Hz to 1 kHz)

AC volts¹ true-rms Range/Resolution 6.000 V / 0.001 V

60.00 V / 0.01 V

600.0 V / 0.1 V

Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)

2.0 % + 3 (500 Hz to 1 kHz)

Continuity Range/Resolution 600 Ω / 1 Ω

Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of

500 μs or longer

Ohms Range/Resolution 600.0 Ω / 0.1 Ω

6.000 kΩ / 0.001 kΩ

60.00 kΩ / 0.01 kΩ

600.0 kΩ / 0.1 kΩ

6.000 MΩ / 0.001 MΩ

Accuracy 0.9 % + 1

Range/Resolution 40.00 MΩ / 0.01 MΩ

Accuracy 5 % + 2

Diode test Range/Resolution 2.00 V / 0.001 V

Accuracy 0.9% + 2

Capacitance Range/Resolution 1000 nF / 1 nF

10.00 μF / 0.01 μF

100.0 μF / 0.1 μF

9999 μF / 1 μF

100 μF to 1000 μF

Accuracy 1.9% + 2

Range/Resolution > 1000 μF

Accuracy 5% + 20%

Lo-Z capacitance Range 1 nF to 500 μF

Accuracy 10% + 2 typical

AC amps true-rms (45 Hz to 500 Hz) Range/Resolution 6.000 A / 0.1 A

10.00 A / 0.01 A

Accuracy 1.5% + 3

20 A continuous overload for 30 seconds max

DC amps Range/Resolution 6.000 A / 0.1 A10.00 A / 0.01 A

Accuracy 1.0% + 3

20 A continuous overload for 30 seconds max

Hz (V or A input)² Range/Resolution 99.99 Hz / 0.01 Hz

999.99 Hz / 0.1 Hz

9.999 Hz / 0.001 Hz

50.00 Hz / 0.01 Hz

 Accuracy 0.1% + 2


Fluke117CDigitalMultimeterNon-ContactACVoltageDetectionMeasuresResistanceContinuityFrequencyCapacita-1983059-1

Fluke117CDigitalMultimeterNon-ContactACVoltageDetectionMeasuresResistanceContinuityFrequencyCapacita-1983059-2

Fluke117CDigitalMultimeterNon-ContactACVoltageDetectionMeasuresResistanceContinuityFrequencyCapacita-1983059-3

Fluke117CDigitalMultimeterNon-ContactACVoltageDetectionMeasuresResistanceContinuityFrequencyCapacita-1983059-4

Fluke117CDigitalMultimeterNon-ContactACVoltageDetectionMeasuresResistanceContinuityFrequencyCapacita-1983059-5


Fluke 117C Digital Multimeter, Non-Contact AC Voltage Detection, Measures Resistance/Continuity/Frequency/Capacitance/Min Max Average, Automatic AC/DC Voltage Selection, Low Impedance Mode

Fluke 117C Digital Multimeter, Non-Contact AC Voltage Detection, Measures Resistance/Continuity/Frequency/Capacitance/Min Max Average, Automatic AC/DC Voltage Selection, Low Impedance Mode

£519.98